MBraun Inert Glove-Box Technology
myMBRAUN Interface upgrade (1518303)
Upgrade: Hardware to be installed in electrical cabinet to allow data communication between the glovebox and myMBRAUN App. ***** Customer should supply network details to MBRAUN, to define the communication settings before shipping ***** Included: communication kit, IBH Link S7++ ***** For Unilab produced before February 2014 and for Labmaster/MB20(0)G Please contact our service dept. to check your version before ordering. ***** Requires installation through MBRAUN Service Additional installation fees apply.
MB-HC-SE1 Upgrade (1518400)
Upgrade: The MB-HC-SE1 analyzer is designed for the detection and monitoring of VOCs (volatile organic compounds) in inert gas or air. Using a photo ionization detector (PID) it is capable of measuring concentrations down to the lower ppm-range (optional: ppb-range). Calibrated for iso-Butene, sensitivities for different other substances can be obtained from tabulated conversion factors. The output voltage signal is scaled 0-10V for 0 to 6000ppm iso-Butene (optional 4-20mA output available). Mounted directly into the circulation piping using the standard KF40 flange. ***** Note: For the intended use (monitoring of a solvent trap = LMF) there is no necessity for an accurate ppm value of a special solvent nor for strict linear response. Typically, mixtures of different substances are to be handled by the LMF and the concentration is low as long as the filter is active. A distinct increase in the signal will indicate exhaust of the filtering material. The PID technology with its combination of low detection limit and large dynamic range is ideally fitted for this application.
First Care Kit - Anatomic gloves (1518500)
Buy a set and save 10%. First care wear part kit consisting of: - 1 pair of anatomic gloves (Art. 1515000) - 2 dust filters - 1 liter oil for vacuum pump - 1 gloveport cover The kit is delivered in a reusable MBRAUN plastic transport box.
First Care Kit - Ambidextrous gloves (1518501)
Buy a set and save 10%. First care waer part kit consisting of: - 1 pair of ambidextrous gloves (Art. 1515001) - 2 dust filters - 1 liter oil for vacuum pump - 1 gloveport cover The kit is delivered in a reusable MBRAUN plastic transport box.
MB-Easyclean-LTBL-22 Internal Upgrade (1518502)
Retrofit kit: Vacuum cleaner for cleaning MB gloveboxes and removal of particles / dust Filter unit is installed inside the glovebox mounted. Main components: - Blower (gas-tight) for suction of the particles with a throughput of approx. 20m
MB-Easyclean-LTBL-88 Internal Upgrade (1518503)
Retrofit kit: Vacuum cleaner for cleaning MB gloveboxes and removal of particles / dust Filter unit is installed inside the glovebox mounted Main components: - Blower (gas-tight) for suction of the particles with a throughput of approx. 84m
MB-Easyclean-LTBL-88 External Upgrade (1518504)
Retrofit kit: Dust cleaner for cleaning MB-Gloveboxes and removal of particles/dust. Filter unit is installed outside the glovebox. Valves for filter change: Uncoupling the Filter housings from Glovebox and Inertisation of the filter housing after filter change. Main components: - Blower (gas-tight) for suction of the particles with a throughput of approx. 84 m
MB-Heat exchanger Upgrade for Unilab (1518601)
Upgrade: for the integration in the gas pipework to the UNILAB glovebox inside the gas purifier unit. The working gas will be cooled effectively through this device; thus the temperature inside the glovebox remains comfortable for the operator. required water flow rate: 3-5 l/min rated cooling power: approx. 800 W
MB-BS-200 Retrofit (1518602)
Box purging system - Upgrade Unit for inerting (purging) of the workspace with inertgas Operation: via operation panel of the gas purifier Valves PLC-controlled Flow rate: max. 200 l/min; incl. manual regulation valve for reduction of the gas flow Functions: - Purging ON / OFF - Max. purging time programmable (0-999 min) The O2 and H2O concentrations are readable during purge (if sensors are installed).
box purge unit 200l/min
MB-LMF-2/40-REG stand alone Retrofit (1518603)
Upgrade for existing system Unit for removal of solvent contaminations from the glovebox atmosphere (LMF) Principle: adsorption Adsorber: Molecular sieve; regenerable Loading: approx. 8 kg Operation modes: a) Inline: circulation of the atmosphere via the LMF with continuous removal b) Bypass: with manual valves, the LMF can be by-passed from the circulation, e.g. during exchange of the adsorber, without breaking the circulation of the gas purifier
MB-LMF-2/40-REG Retrofit (1518605)
Unit for removal of solvent contaminations from the glovebox atmosphere (LMF) Upgrade Principle: adsorption Adsorber: Molecular sieve; regenerable Regeneration: PLC-controlled program sequence; operation via Touch panel Loading: approx. 8 kg Operation modes: a) Inline: circulation of the atmosphere via the LMF with continuous removal b) Bypass: with electro.-pneum. valves, the LMF can be by-passed from the circulation, e.g. during exchange of the adsorber, without breaking the circulation of the gas purifier ******** MB-UGP-Solvent Sensor available as an option upon request for Unilab Plus/Pro, Labmaster Pro, MB20/200 ******** When using Acetonitrile please contact M. Braun
MB-ECO-Mode Upgrade (1518606)
For a consumption-optimised operation of all MBRAUN Glovebox Workstations and gas purifications. This includes: - Vacuum pump can be turned off when the antechambers not used for a long time - Pressure control without vacuum pump in overpressure operation - Optimized blower performance with reduced power consumption - Automatic light switch off This results in energy savings of up to 90% and minimizes the noise pollution in the laboratory
MB-quartz sensor Retrofit (1518800)
Quartz oscillator for thin film measurement - flexible positioning - height adjustable - water-cooled - incl. 10 pcs. spare crystals
MB-thermal evaporator_single upgrade (1518801)
Single type thermal resistance evaporator, upgrade Rating: 10V @ 200A = 2kVA 2 pcs. water-cooled high voltage feedthroughs 1 pc. power supply (transformer and thyristor controller)
Upgrade high reinforced frame (1500024-780/2000)
Reinforced frame, 60 mm x 60 mm For Modular glovebox 780/2000 Maximal load: 800 kg (with possibility to move the system with the castors) Maximal load: 1.000 kg (when the system stays always on the feet, in this case the system can
up to a maximum load of 1.000 kg in the box
MB-Service-Magnet incl. removable pen (1510112)
The little, practical planner can be placed magnetically on the light strip of your glovebox.
It offers you the possibility to date the exchange of different spare parts.
Therefore you always have a perfect overview of when the next replacement is scheduled.
You can easily remove the inscription with the enclosed pen to update the data on the planner.
It offers you the possibility to date the exchange of different spare parts.
Therefore you always have a perfect overview of when the next replacement is scheduled.
You can easily remove the inscription with the enclosed pen to update the data on the planner.
Part-No.: 1510112
Clamping cover antechamber, D=100mm (1510000)
Antechamber cover with clamping closure for a 100mm diameter antechamber. (Original item number: 7003367)
Part-No: 1510000
Glove downholder (lentgh 850mm) (1510114)
The downholder is used to tie the gloves away downwards in the event of overpressure so that they do not take up space in your laboratory in case they are not used. This length is suitable for boxes with a width/length of 1200mm to 1250mm.
Part-No: 1510114
Glare strip for glovebox window l=1100mm; b=70mm (1510102)
(Original item number: 2600735)
Part-No: 1510102