MBRAUN Spares And Parts
Maintenance kit cell replacement for MB-HC-SE1 (1511505)
This replacement kit contains a new cell with optics, which is designed to be replaced directly by the customer upon receipt.
A calibration of the electronics is nevertheless necessary in certain cases. Therefore a declaration about decontamination is required for each unit.
The online form is available to every logged-in user under the "Self Service" menu. Alternatively a PDF version is available.
Maintenance kit cell exchange for MB-HC-SE1 (1511506)
This exchange kit contains a cell with Optics designed so that it can be exchanged on receipt be exchanged directly by the customer himself. After you've removed your cell, you are obligated to send your analyzer within 2 weeks to MBRAUN. If you do not send your analyzer to MBRAUN within the specified time period, MBRAUN will charge you an additional charge. For processing, a declaration about decontamination is required per device. On the basis of this declaration the viability of the exchange can be easily determined. The online form is available to every logged-in user under the "Self Service" menu. Alternatively a PDF version is available.
Analyzer MB-OX-SE1, 0-1000ppm, 0-10V (1511600)
The MB-OX-SE-1 analyzer has been designed to monitor the atmosphere of MBRAUN Systems for residual Oxygen content. The measuring range is 0 to 1000 ppm. (Original item number: 1500686)
Analyzer MB-OX-SE3, 0-25%, 0-10V (1511601)
The oxygen analyzer MB-OX-SE-3 is designed to monitor the amount of oxygen in nitrogen, argon or helium in inert gas systems. The sensor has a wide range from 0 to 25 vol% of oxygen concentrations. The analyzer can be operated with PLC-systems, which are integrated in MBRAUN systems as standard equipment, or with MB-SSD-DIS monitors, which are available separately. (Original item number: 1500686)
Analyzer MB-OX-SE3, 0-25%, 4-20mA (1511602)
The oxygen analyzer MB-OX-SE-3 is designed to monitor the amount of oxygen in nitrogen, argon or helium in inert gas systems. The sensor has a wide range from 0 to 25 vol% of oxygen concentrations. The analyzer can be operated with PLC-systems, which are integrated in MBRAUN systems as standard equipment, or with MB-SSD-DIS monitors, which are available separately. (Original item number: 1500823)
Analyzer MB-OX-SE1, 0-1000ppm, 4-20mA (1511603)
The MB-OX-SE-1 analyzer has been designed to monitor the atmosphere of MBRAUN Systems for residual Oxygen content. The measuring range is 0 to 1000 ppm. (Original item number: 1500686)
Analyzer MB-MO-SE1, 0-500ppm, 0-10V (1511610)
The MB-MO-SE-1 analyzer has been designed to monitor the atmosphere of MBRAUN Systems for residual Moisture content. Please note that the sensor head must be coated regularly with 85% phosphoric acid. The measuring range is 0 to 500 ppm. (Original item number: 1500685)
Analyzer MB-MO-SE1, 0-500ppm, 4-20mA (1511611)
The MB-MO-SE-1 analyzer has been designed to monitor the atmosphere of MBRAUN Systems for residual Moisture content. Please note that the sensor head must be coated regularly with 85% phosphoric acid. The measuring range is 0 to 500 ppm. (Original item number: 1500686)
Analyzer-Set MB-OX-SE1 and MB-MO-SE1, 0-10V (1511612)
Buy as a set and save 5%. MB-MO-SE1: Monitoring the atmosphere of MBRAUN systems for residual moisture Measuring range: 0-500ppm Please note that the sensor head must be coated regularly with 85% phosphoric acid. MB-OX-SE1: Monitoring the atmosphere of MBRAUN systems for residual oxygen content Measuring range: 0-1000ppm (Original item number: 1500685, 1500686)
Analyzer MB-OX-EC, 0-1000ppm, 0-10V, sas w/o CO2 (1511620)
Electrochemical Oxygen analyzer to be used when atmosphere is not dry or when a lot of solvent vapors are present. The analyzer MB-OX-EC monitors the oxygen content in inert gases. The analyzer can be used in combination with the system control (PLC) of MBRAUN standard systems or as standalone oxygen-measuring-system with the optionally available MBRAUN SSD-DIS combi-monitor. (Original item number: 1500716)
Analyzer MB-OX-EC, 0-1000ppm,4-20mA, Gas w/o CO2 (1511621)
Electrochemical Oxygen analyzer to be used when atmosphere is not dry or when a lot of solvent vapors are present. The analyzer MB-OX-EC monitors the oxygen content in inert gases. The analyzer can be used in combination with the system control (PLC) of MBRAUN standard systems or as standalone oxygen-measuring-system with the optionally available MBRAUN SSD-DIS combi-monitor. (Original item number: 1500816)
Analyzer MB-OX-EC, 0-1000ppm, 0-10V, Gas with CO2 (1511622)
Electrochemical Oxygen analyzer to be used when atmosphere is not dry or when a lot of solvent vapors are present. The analyzer MB-OX-EC monitors the oxygen content in inert gases. The analyzer can be used in combination with the system control (PLC) of MBRAUN standard systems or as standalone oxygen-measuring-system with the optionally available MBRAUN SSD-DIS combi-monitor. (Original item number: 1500716)
Analyzer MB-OX-EC, 0-1000ppm, 4-20mA, Gas with CO2 (1511623)
Electrochemical Oxygen analyzer to be used when atmosphere is not dry or when a lot of solvent vapors are present. The analyzer MB-OX-EC monitors the oxygen content in inert gases. The analyzer can be used in combination with the system control (PLC) of MBRAUN standard systems or as standalone oxygen-measuring-system with the optionally available MBRAUN SSD-DIS combi-monitor. (Original item number: 1500818)
Analyzer MB-OX-EC, 0-25%, 0-10V (1511624)
Electrochemical Oxygen analyzer to be used when atmosphere is not dry or when a lot of solvent vapors are present. The analyzer MB-OX-EC monitors the oxygen content in inert gases. The analyzer can be used in combination with the system control (PLC) of MBRAUN standard systems or as standalone oxygen-measuring-system with the optionally available MBRAUN SSD-DIS combi-monitor. Measuring range: 0 to 25% (Original item number: 1500819)
Analyzer MB-OX-EC, 0-25% O2, 4-20mA (1511625)
Electrochemical Oxygen analyzer to be used when atmosphere is not dry or when a lot of solvent vapors are present. The analyzer MB-OX-EC monitors the oxygen content in inert gases. The analyzer can be used in combination with the system control (PLC) of MBRAUN standard systems or as standalone oxygen-measuring-system with the optionally available MBRAUN SSD-DIS combi-monitor. Measuring range: 0 to 25% (Original item number: 1500820)
Analyzer MB-HC-SE1, 0-6000 ppm,0-10V (1511630)
The MB-HC-SE1 analyzer is designed for monitoring
of VOCs (volatile organic compounds) in
inert gases or air.
Since the sensor is calibrated for hexane, the
Solvent detectable depending on RF-factor.
Measuring range: 0-6000ppm
The measured value can be displayed via the system control (SPS)
of MBRAUN standard systems or above the
optionally available independent MBRAUN
SSD-DIS combination monitor.
Calibration must be performed by MBRAUN
will be.
(Original item number: 1500678)
Analyzer MB-UGP-H2 in Ar, 0-10% (1511640)
Analyzer for measuring hydrogen in argon atmosphere. Measuring range: 0-10% Operating voltage: 110-240VAC The UGB is supplied with the sample gas of the box by a closed loope system. The measured value can be displayed via the system control (SPS) of MBRAUN standard systems or above the optionally available independent MBRAUN SSD-DIS combination monitor. Calibration must be performed by MBRAUN will be. (Original item number: 1500802)
Analyzer MB-UGP-H2 in N2, 0-10% (1511641)
Analyzer for measuring hydrogen in nitrogen atmosphere. Measuring range: 0-10% Operating voltage: 110-240VAC The UGB is supplied with the sample gas of the box by a closed loope system. The measured value can be displayed via the system control (SPS) of MBRAUN standard systems or above the optionally available independent MBRAUN SSD-DIS combination monitor. Calibration must be performed by MBRAUN will be. (Original item number: 1500803)
Analyzer MB-UGP-He in N2, 0-20% (1511642)
Analyzer for measuring helium in nitrogen atmosphere. Measuring range: 0-20% Operating voltage: 110-240VAC The UGB is supplied with the sample gas of the box by a closed loope system. The measured value can be displayed via the system control (SPS) of MBRAUN standard systems or above the optionally available independent MBRAUN SSD-DIS combination monitor. Calibration must be performed by MBRAUN will be. (Original item number: 6000252)
Analyzer MB-UGP-He in Ar, 0-30% (1511643)
Analyzer for measuring helium in argon atmosphere. Measuring range: 0-30% Operating voltage: 110-240VAC The UGB is supplied with the sample gas of the box by a closed loope system. The measured value can be displayed via the system control (SPS) of MBRAUN standard systems or above the optionally available independent MBRAUN SSD-DIS combination monitor. Calibration must be performed by MBRAUN will be. (Original item number: 6000257)