Edwards Vacuum Leak Detectors

Sort By:  
New Edwards ELD500 Dry Portable Leak Detector With Integral Diaphragm Pump, 200-240V,50/60Hz, D13520903
New Edwards ELD500 Wet Portable Leak Detector With Integral Oil Sealed Rotary Vane Pump, 200-240V,50/60Hz, D13510903
New Edwards ELD500 Flex Portable Leak Detector With Connections For External Backing Pump, 100-240V,50/60Hz, D13530000
Edwards ELD500 Dry Portable Leak Detector With Integral Diaphragm Pump 200-240V,50/60Hz, D13520903 (D13520903)
Features:
Edwards ELD 500 Dry D13520903 Bench Top Leak Detectors
FULL 18-MONTH WARRANTY!
The ELD500 precision leak detector is designed for fast, accurate leak detection in a wide range of applications, fully mobile and with an easy to control interface. Featuring with low energy consumption, extended warranty and even longer life ion source, Edwards ELD500 leak detector ensures exceptional low cost of ownership with no compromise on performance.Available in three variants: FLEX, WET and DRY, Edwards ELD500 leak detector is versatile. All models feature a rugged turbomolecular pump optimised for the rigours of portable leak detection, ideal across all applications.Edwards ELD500 Brochure and DataSheet available below. Edwards Leak Detector Available in Three Models: Wet, Dry, Flex WET version with an integrated oil sealed rotary vane pump DRY version with an integrated helium optimised diaphragm pump FLEX version without a primary pump, ideal for trolley mounting along with a larger primary pump such as an Edwards nXDS scroll pump New Edwards ELD 500 Wet Offer the Following Additional Features: FLEXIBLE REMOTE CONTROL OPTIONS Colour touch screen control with local graphical display and audible leak detection. Wireless models allow simultaneous control of up to 10 leak detectors. MOBILE SOLUTION Low weight and integrated carry handles which allow it to be bench top or trolley mounted. HIGH SENSITIVITY Measurement of leaks for Helium of <5x10-12mbar ls-1 in vacuum mode and <7x10-9mbar ls-1 in sniffer mode. PARTIAL FLOW KIT Allows effective pump down of large of contaminate flows compatible with WET and FLEX variants. ACCURATE PIN-POINTING OF LEAKS Standard sniffer line enables operation up to 4m from the ELD500. Longer sniffer lines of up to 50m can be used with the sniffer extender interface. LONG TERM STABILITY Ensured by class leading 180° mass spectrometer.



New Edwards ELD500 Dry Portable Leak Detector With Integral Diaphragm Pump, 200-240V,50/60Hz, D13520903
Edwards ELD500 Wet Portable Leak Detector With Integral Oil Sealed Rotary Vane Pump 200-240V,50/60Hz, D13510903 (D13510903)
Features:
Edwards ELD 500 Wet D13510903 Bench Top Leak Detectors
FULL 18-MONTH WARRANTY!
The ELD500 precision leak detector is designed for fast, accurate leak detection in a wide range of applications, fully mobile and with an easy to control interface. Featuring with low energy consumption, extended warranty and even longer life ion source, Edwards ELD500 leak detector ensures exceptional low cost of ownership with no compromise on performance.Available in three variants: FLEX, WET and DRY, Edwards ELD500 leak detector is versatile. All models feature a rugged turbomolecular pump optimised for the rigours of portable leak detection, ideal across all applications.Edwards ELD500 Brochure and DataSheet available below. Edwards Leak Detector Available in Three Models: Wet, Dry, Flex WET version with an integrated oil sealed rotary vane pump DRY version with an integrated helium optimised diaphragm pump FLEX version without a primary pump, ideal for trolley mounting along with a larger primary pump such as an Edwards nXDS scroll pump New Edwards ELD 500 Wet Offer the Following Additional Features: FLEXIBLE REMOTE CONTROL OPTIONS Colour touch screen control with local graphical display and audible leak detection. Wireless models allow simultaneous control of up to 10 leak detectors. MOBILE SOLUTION Low weight and integrated carry handles which allow it to be bench top or trolley mounted. HIGH SENSITIVITY Measurement of leaks for Helium of <5x10-12mbar ls-1 in vacuum mode and <7x10-9mbar ls-1 in sniffer mode. PARTIAL FLOW KIT Allows effective pump down of large of contaminate flows compatible with WET and FLEX variants. ACCURATE PIN-POINTING OF LEAKS Standard sniffer line enables operation up to 4m from the ELD500. Longer sniffer lines of up to 50m can be used with the sniffer extender interface. LONG TERM STABILITY Ensured by class leading 180° mass spectrometer.



New Edwards ELD500 Wet Portable Leak Detector With Integral Oil Sealed Rotary Vane Pump, 200-240V,50/60Hz, D13510903
Edwards ELD500 Flex Portable Leak Detector With Connections For External Backing Pump 100-240V, 50/60Hz, D13530000 (D13530000)
Features:
Edwards ELD 500 Flex D13530000 Bench Top Leak Detectors
FULL 18-MONTH WARRANTY!
The ELD500 precision leak detector is designed for fast, accurate leak detection in a wide range of applications, fully mobile and with an easy to control interface. Featuring with low energy consumption, extended warranty and even longer life ion source, Edwards ELD500 leak detector ensures exceptional low cost of ownership with no compromise on performance.Available in three variants: FLEX, WET and DRY, Edwards ELD500 leak detector is versatile. All models feature a rugged turbomolecular pump optimised for the rigours of portable leak detection, ideal across all applications.Edwards ELD500 Brochure and DataSheet available below. Edwards Leak Detector Available in Three Models: Wet, Dry, Flex WET version with an integrated oil sealed rotary vane pump DRY version with an integrated helium optimised diaphragm pump FLEX version without a primary pump, ideal for trolley mounting along with a larger primary pump such as an Edwards nXDS scroll pump New Edwards ELD 500 Wet Offer the Following Additional Features: FLEXIBLE REMOTE CONTROL OPTIONS Colour touch screen control with local graphical display and audible leak detection. Wireless models allow simultaneous control of up to 10 leak detectors. MOBILE SOLUTION Low weight and integrated carry handles which allow it to be bench top or trolley mounted. HIGH SENSITIVITY Measurement of leaks for Helium of <5x10-12mbar ls-1 in vacuum mode and <7x10-9mbar ls-1 in sniffer mode. PARTIAL FLOW KIT Allows effective pump down of large of contaminate flows compatible with WET and FLEX variants. ACCURATE PIN-POINTING OF LEAKS Standard sniffer line enables operation up to 4m from the ELD500. Longer sniffer lines of up to 50m can be used with the sniffer extender interface. LONG TERM STABILITY Ensured by class leading 180° mass spectrometer.



New Edwards ELD500 Flex Portable Leak Detector With Connections For External Backing Pump, 100-240V,50/60Hz, D13530000
Per Page      1 - 3 of 3
  • 1